Wednesday, 21 May 2014

SUPPOSITORY REPORT

Title:

Evaluation of the effect of different formulation on suppository characteristics.

Objective:

To study the effect of different composition of base on the physical characteristic of suppositories.

Introduction:

            Suppositories are designed for rectum administration and usually consist of the active drug(s) and a base which is designed to melt at body temperature. Once the suppository has been rectally administered the base will then break down and the drug will be released. The rectum route however provides an excellent route for drug absorption and therefore can be used in patients with swallowing difficulties or for drugs where avoidance of the stomach is preferable. Additionally by avoiding the stomach the drug also misses the first passed metabolism which is the liver where the most commonly the drug will be metabolise due to the enzymes. Therefore in many cases more of the drug will get into the system and a lower
            Good suppository will melt after the rectal administration and release the drug either topically or systematically. The medicament is incorporated into a base such as PEG which slowly dissolves in the mucous secretions. The ideal suppository base should be non-toxic, non-irritating, inert, compatible with medicaments, and easily formed by compression or moulding. Different composition of bases will affect the rate and limit of release of the drug from the suppository.
            In this experiment, the effects of the different base composition to the suppository physical characteristics and also to the drug release characteristics are evaluated.

Apparatus:
Analytical balance                              Water bath 37oC
Weighing boats                                  Dialysis bag
Spatula                                              Glass rod
50ml and 100ml beaker                     5ml pipette
Hotplate                                            Plastic cuvettes
5ml measuring cylinder                       Spectrophotometer UV/Vis
Suppository mould set
Materials:
Polyethylene glycol (PEG) 1000
Polyethylene glycol (PEG) 6000
Paracetamol
Distilled water

Procedures:

1. 10g of suppository is prepared using the formulation below:


Suppository
Group
PEG 1000
(g)
PEG 6000
(g)
Paracetamol (g)
Total
(g)
I
1,5
9
0
1
10
II
2,6
6
3
1
10
III
3,7
3
6
1
10
IV
4,8
0
9
1
10


 Some of the procedure preparing suppositories 




2. The suppository is moulded using the suppository mould. The shape, texture and colour of the suppository is observed and discussed.
our 'fresh' suppository


3. One suppository is placed into a beaker containing 10ml of distilled water which is placed into the water bath at 37oC and the time required for the suppository to melt is recorded.
    
The tougher time !! entering suppository into dialysis bag.

4. One suppository is inserted into a dialysis bag and both ends are tied neatly, as shown in the figure below. It is then placed into a beaker containing 50mL of distilled water which is then placed inside the water bath at 37oC.

5. The sample is pipetted (3- 4mL) in 5 minutes interval and the release of Paracetamol from the suppository is determined using the UV-visible spectrometer. The distilled water must be stirred first before the sample is taken.

Result and discussion :

1. Compare the physical characteristics of suppositories that formulated and give comment.


Formulation
I
II
III
IV
Formulation
Group
1
5
2
6
Group
1
5
2
Shape
Bullet
Bullet
Bullet
Bullet
Shape
Bullet
Bullet
Bullet
Texture
Dull, greasy,
Dull,  greasy
Dull,  greasy
Dull,  greasy,  hard to break
Texture
Dull, greasy,
Dull,  greasy
Dull,  greasy
Color
White
White
White
White
Color
White
White
White

            Based on the experiment, all the suppositories have the shape of a bullet since the mould that being used is of this shape. The quantities of PEG 1000 and PEG 6000 different for each group and this will lead to formation of suppositories with different physical characteristics.
             From the table, the hardness of the suppositories increase across the groups. This is due to the amount of PEG 6000 used. This could be explained, as the physicochemical characters of PEG 6000 forms more strong and stable hydrogen bonds in the suppository compared to PEG 1000. PEG 6000 is higher molecular weight compare to PEG 1000. Thus, it also has a lot of hydroxyl groups which can form numerous hydrogen bonds between the molecules of the PEG 6000 and the molecules of Paracetamol.
            Greasiness characteristic of the suppositories are both related to the amount and effect of PEG 1000, which is considered more hydrophobic than PEG 6000. As we can see, the amount of PEG 1000 decreases across the four formulations, and hence the greasiness decrease in the same degree.
             As for the colour of suppositories, since the active ingredient that we used is paracetamol which is white in colour, the colour of the suppositories produce is white in colour.

2. Plot a graph of the time needed to melt the suppository vs. the amount of PEG 6000 in the formulation. Compare and explain the results.


Suppository
Group
Time required to dissolved the suppository (minutes)
Mean, x
Standard deviation, SD
I
1
40.45
36.49
3.97
5
32.52
II
2
30.56
39.78
9.22
6
49.00
III
3
46.36
39.68
6.68
7
33.00
IV
4
43.32
37.19
6.13
8
31.06

Composition of PEG 6000 (g)
0
3
6
9
Mean of minutes (min) (x ̅ ± SD)
36.49±3.97
39.78± 9.22
39.68±6.68
37.19±6.13

                        

             Polyethylene glycol (PEG) is a water soluble base which is it has the highest water miscibility among the water miscible base, absorption base and hydrocarbon base. It possessed many desirable properties. They are chemically stable, nonirritating, miscible with water and mucous secretion. It is also can be formulated either by molding and compression in a wide range of hardness and melting point. It acts as lyophilic base in the suppository paracetamol prepared which influence the dissolution rate of the suppository and the time taken for the suppository to melt. 
              In this experiment, there are two type of PEG used which are PEG 1000 and PEG 6000. PEG 6000 has higher molecular weight compared to PEG 1000. The higher the molecular weight of PEG, making it less interacts with the water molecule by using the hydrogen bond. It is therefore, in this experiment PEG 6000 has the lower possibility to absorb water compared to PEEG 1000. This will then affect the dissolution rate where the suppository with the higher PEG 6000 content will melt slower in the distilled water.
               Based on the graph above, it showed that the time taken for the suppository to melt increased as the content of PEG 6000 used increases from 0 g to 6 g. However, there is slightly decrease in time for the suppository to melt when 9 g of PEG 6000 is used. According to the theory on the above graph, the results obtained have some errors. It is supposedly decrease in time for the suppository to melt when higher content of PEG 6000 is used. There might be some errors that affecting the results obtained. The errors might be happened during the preparation of the suppository. The preparation methods that is applied by each group may be vary and thus affecting the uniformity of the suppository. Besides that, the water temperature might be not fix at 37 ℃ as it is difficult to controlled. The suppositories may also not solidify completely as the time taken for the suppositories to solidify in the fridge is not being set. This will then affect the results if the incomplete solidified suppository is put into the water bath in the step to determine the dissolution rate of the suppository.

3) Plot the graph of UV absorption against time (Procedure 6). Give your comments.

Average UV absorption at 520 nm ( x ± SD )

0
5
10
15
20
25
30
35
40
45
50
G 1
0.003
0.006
0.053
0.054
0.028
0.029
0.050
0.012
0.008
0.012
0.022
     G  5
0.012
0.016
0.016
0.026
0.019
0.018
0.021
0.021
0.021
0.097
0.020
Average 
0.008
0.011
0.035
0.040
0.024
0.024
0.036
0.017
0.015
0.055
0.021

                              

               According to the graph plotted based on our result, the release rate of paracetamol is not stable throughout the time. Theoretically, the graph should be in sigmoid shape which indicates constant drug release rate until equilibrium is achieved. However, the graph still showing peak and trough throughout the experiment which indicates that the drug is not releasing at a constant rate for PEG 6000 formulation.
               At the 55th minutes, amount of paracetamol released into water in beaker shoots up. This is because there is a great difference in concentration gradient between water in beaker and suppository in dialysis bag. Therefore, paracetamol diffuses out quickly.
               This graph deviates from the theory may be because of errors that occurred when we conduct the experiment. Firstly, uneven heating of water bath which will lead to inconstant drug release rate from the suppository. Besides that, the suppository we made may not be homogenously formed. This may cause the brittleness of PEG suppository or trapped air space in the suppository thus reducing the size and altering the drug release rate of drug from suppository dosage form. In addition to that, distilled water in which the dialysis bag is exposed to may not be stirred evenly before it is taken to be tested on spectrophotometer UV/Vis.
             In this experiment, paracetamol needs to pass through the dialysis bag before it can reach distilled water. Dialysis bag represents human biological membrane while the distilled water represents human blood plasma. The melting process,drug release and drug absorption processes occur in water bath at 37ºC, which represents human body temperature.
4. Plot a graph of UV absorption for different composition of suppository formulations against time. Compare and explain the results.

Time (min)
Average UV Absorption at 300nm ( x ± SD )

0
5
10
15
20
25
30
Emulsifying Ointment
I
Group 1
0.030
0.068
0.076
0.095
0.112
0.128
0.157
Group 5
0.015
0.056
0.056
0.094
0.109
0.121
0.172
Average

0.023
0.062
0.066
0.095
0.111
0.125
0.165
SD

0.0106
0.0085
0.0141
0.0007
0.0021
0.0049
0.0106
II
Group 2
0.025
0.450
0.492
0.527
0.553
0.581
0.590
Group 6
0.073
0.120
0.140
0.180
0.243
0.263
0.286
Average

0.049
0.285
0.316
0.354
0.398
0.422
0.438
SD

0.0339
0.2333
0.2489
0.2454
0.2192
0.2249
0.2150
III
Group 3
0.035
0.042
0.046
0.055
0.058
0.062
0.070
Group 7
0.039
0.040
0.113
0.101
0.162
0.192
0.239
Average

0.037
0.041
0.080
0.078
0.110
0.127
0.155
SD

0.0028
0.0014
0.0474
0.0325
0.0735
0.0919
0.1195
IV
Group 4
0.063
0.121
0.212
0.224
0.235
0.294
0.331
Group 8
0.100
0.183
0.224
0.221
0.222
0.240
0.311
Average

0.082
0.152
0.218
0.223
0.229
0.267
0.321

SD

0.0262
0.0438
0.0085
0.0021
0.0092
0.0382
0.0141

                                             

                  In the graph we plotted, we can say that the average UV absorption for all the formulation increase with time. This is because the increase in the concentration of the acetylsalicylic acid in the beaker that consisted of dialysis bag. 3-4ml of aliquot in the beaker was taken and sent to analysis for every 5 minutes. The ointment that contains active ingredient has been released gradually into the solution from time to time. Hence, the concentration of the active ingredient which is acetylsalicylic acid increases progressively and it is indicated by the increases in the UV absorption.
                  From this graph, we can see that the standard deviations of all different formulations are not consistent. There is a great decrease in the formulation I at the 15th minute. It drops from 0.0141 to 0.0007. Then it increases again to 0.0106 at 30th minute. In the formulation II, it rises sharply from 0.0339 to 0.2333 at the 5th minute. After that, it maintains at the range of 0.2150 to 0.2489. These examples show that there are errors occurred in the experiment that has been carried out.
                  Theoretically, the formulation IV should have the highest reading of released acetylsalicylic acid. Instead, the actual reading that we obtained from the plotted graph is the lowest among other formulation. This may due to the presence of low emulfsying wax that causes the matrix not fine enough to trap liquid paraffin and soft paraffin. This incomplete matrix is then causes the ointment to be unstable and it cannot disperse evenly. This leads to the hydrophilic ointment to diffuse into the distilled water through the membrane and causes inaccurate of results.
                   Next, diffusion of drug from the ointment is directly affected by the formulation. Formulation IV which has the lowest amount of emulsifying wax and highest amount of liquid paraffin should release most of the active ingredient from the ointment. Then, the rate of release is followed by formulation III, II and I.

                                                                IV>III > II > I
                                                  Decreasing rate of drug diffusion

                  This is because the ointment IV has the least amount of emulsifying wax in which it is less stable to trap the liquid and soft paraffin. Thus, it formed an unstable ointment. As a result, this leads to the hydrophilic ointment to diffuse into the distilled water through the membrane.
                  However, the graph we obtained after the experiment is different from the expected result. The result we obtained is in the following manner.
                                                                 II>IV>III>I
                                                Decreasing rate of drug diffusion

                   The conflict in result might due to errors done during the experiment. Firstly, the ointment is not well prepared whereby it directly affects the rate of drug diffused. Next, the active ingredient is not well distributing in the mixture and results in non-homogenous mixture. Therefore, this contributes to the abnormal rate of the drug diffusion. Next, the dialysis bag is not well tight which the ointment may leak out and obtained the result higher than it supposed to be. On the other hand, the outer membrane of dialysis bag may contaminated by the ointment during the filling process. Thus, the rate is affected. . More than that, there was splitation occurred when carrying the practical. The solution from that particular beaker may contaminated other solutions as all the beakers shared the same water bath. Last but not least, there is great difference in values of UV absorption between group 1 and 5 which results in large standard deviation. This probably due to different preaparation techniques or one of the group did not stir the solution well each time when taking out solution from the beaker.

5. What are the functions of all materials used in this suppository preparation? How can the different contents of PEG 1000 and PEG 6000 affect the physical characteristics of the formulation of a suppository and the rate of release of drug from it?

              In this experiment, polyethylene glycol (PEG) with different molecular weight are used which are PEG 1000 and PEG 6000. Polyethylene glycol with different molecular weight determines the melting points of the suppositories. Polyethylene glycol functions as carrier base, solubilizer and absorption enhancer for the active ingredients, normally drugs (the active ingredient in this experiment is Paracetamol). PEG increases the effective dispersion and as it degrades, it enhances the delivery of drug through the rectal route by diffusing out from the PEG. The drug will released by melting of PEG within the body or by dissolving in the body fluids. As mentioned before, different molecular weight of PEGs will contribute different rate of melting. Thus, suitable combinations of different PEGs will help the drug to achieve optimum rate of drug release from the suppository, ensuring the drug to be released easily and too strongly sustained in the carrier base. Consequently, the rate of absorption through the rectal mucosa and bioavailability increases.
               Paracetamol in this experiment acts as the only active ingredient that will exert the therapeutic effects in the body. Paracetamol in suppository normally are used in kids, or patients who are having symptoms of vomiting and nausea. Paracetamol functions as painkiller and antipyretic agent.
               The use of different content of PEGs with different molecular weights which are PEG 1000 and PEG 6000 in this experiment will result in different effects on the physical characteristics of the suppositories and eventually influence the rate of drug released from the suppositories. The suppositories that have more PEG 6000 will increase hardness of the suppository and the difficulty of the drug to be released from the suppository. This is because there will be more hydrogen bonds are formed between the PEG 6000 molecules and drug molecules when more PEG 6000 is used. PEG 1000 will produce softer suppository and will release the drug easier compared to PEG 6000. Thus, it is important to have the correct combination ratio of PEG 1000 and PEG 6000 to avoid producing the suppositories which are extremely hard or soft. The appropriate combination of PEG 1000 and PEG 6000 will give rise to the balance between the lipophilicity and hydrophilicity of the bases, thus giving the optimum ability to carry the drugs in the delivery system and ability to release the drug at the optimum rate, obtaining the optimum bioavailability.

CONCLUSION : 

The different percentage of combination of PEG 1000 and PEG 6000 will affect the physical characteristics and the drug release rate from the suppository. The higher the amount of PEG 6000, the suppository will be harder.

REFERENCES :

1. Rita Bhatta and Mohammad Salim Hossain, 2011. Evaluation of Kollidon SR based Ketorolac Tromethamine Loaded Transdermal Film. Journal of Applied Pharmaceutical Science 01 (08); 2011: 123-127.

2. http://www.pharmpress.com/product/9780857110930/suppositories

Some of our memories and there's a lot we learn :
Opps ~~ one of it broken ~



Ainina, what are you looking at ?? any problems?
ohh, no ! my dialysis bag.




























No comments:

Post a Comment